| Version | Date | Author | Changes |
|---|---|---|---|
| 1.0 | 01/04/2025 | Sean Ashton | Initial issue (S.O.P 7.1 / 7.2) |
| 2.0 | 17/02/2026 | Sean Ashton | Consolidated to flowchart procedure format — staff model, manuals as core reference |
ISO 9001 Cl. 10.2 • ISO 14001 Cl. 10.2 • ISO 45001 Cl. 10.2 — Nonconformity and corrective action
HREG08 with root cause analysis, corrective actions, and effectiveness verification.| Finding Type | Containment | Root Cause | CA Due | Verification |
|---|---|---|---|---|
| Major NC | Immediate | 5 working days | 30 days | 60 days |
| Minor NC | 5 working days | 10 working days | 90 days | 120 days |
| OFI | N/A | N/A | Next review cycle | Next audit |
| Customer Complaint | Immediate acknowledgment | 5 working days | 30 days | 60 days |